aboutsummaryrefslogtreecommitdiff
path: root/src
AgeCommit message (Collapse)Author
2022-12-08Fix Teltonika temperature (fix #4993)Anton Tananaev
2022-12-06Fix DMT Bolt2 alarmsAnton Tananaev
2022-12-04Improve permissions checkAnton Tananaev
2022-12-02Decode Cellocator CR300 reasonAnton Tananaev
2022-12-02Fix DualCam init responseAnton Tananaev
2022-11-27Update java versionsAnton Tananaev
2022-11-27Unknown device throttlingAnton Tananaev
2022-11-27Support GL600 GPS lockAnton Tananaev
2022-11-24ATrack AK11 text responsesAnton Tananaev
2022-11-23Add TT18 4G test caseAnton Tananaev
2022-11-22Fix steps decodingAnton Tananaev
2022-11-16Fix missing deviceAnton Tananaev
2022-11-14Customizable Kafka topicAnton Tananaev
2022-11-13Implement Kafka forwardingAnton Tananaev
2022-11-13Refactor position forwardingAnton Tananaev
2022-11-13Refactor event forwardingAnton Tananaev
2022-11-13Fix manager permission (fix #4982)Anton Tananaev
2022-11-10Add commentAnton Tananaev
2022-11-06Handle missing cacheAnton Tananaev
2022-11-04Clean up command resourceAnton Tananaev
2022-11-03Add MD500S heartbeat responseAnton Tananaev
2022-11-03Fix responseAnton Tananaev
2022-11-03Reuse checksum codeAnton Tananaev
2022-11-02Improve attribute type handlingAnton Tananaev
2022-11-01Better Meiligao commandsAnton Tananaev
2022-11-01Improve permission checkAnton Tananaev
2022-10-28Address in events report (fix #4761)Anton Tananaev
2022-10-28Missing iStartek parametersAnton Tananaev
2022-10-27Support Teltonika DualCam videoAnton Tananaev
2022-10-27Fix DT700 temperature decodingAnton Tananaev
2022-10-26Remove duplicate tokenAnton Tananaev
2022-10-26added MaintenanceEventHandlerTestjcardus
2022-10-26Update MaintenanceEventHandler.javajcardus
trailing spaces
2022-10-262 Bugs on maintenance jcardus
According to the documentation: "Traccar can help control maintenance intervals of devices. There are two attributes to configure: maintenance.start and maintenance.interval. They can be set in device, group or server attributes. Traccar generates event every time totalDistance attribute gets over maintenance.start + maintenance.interval * N value where N is a natural number. Example: maintenance.start=6000000, maintenance.interval=8000000 Events will be generated when totalDistance goes over 6000 km, 14000 km, 22000 km and so on." In this example, the event won't be fired when it goes over 6000 km. If maintenance.interval < maintenance.start and maintenance.start is multiple of maintenance.interval then the event will be fired before maintenance.start because the comparison will be on negative numbers. Another solution would be to use absolute numbers on the comparison. Example: maintenance.start = 10 000 000 maintenance.interval = 2 000 000 the event will be fired when it goes over 2 000 000 the event wont' be fired when it goes over 10 000 000
2022-10-26Huabao: code style - orderingBen Harris
Co-authored-by: Anton Tananaev <anton.tananaev@gmail.com>
2022-10-25Huabao Protocol: Add CC888 heartbeat packetBen Harris
From CC888 protocol When vehicle engine is OFF, the device will stop uploading location information to platform server, it will send heart beat message to platform server every 2 minutes, the heart beat message ID is 0x0506, the message body of heart beat message is empty. The platform will reply device with general replay message ID 0x8001
2022-10-20Update GPS103 command (fix #4964)Anton Tananaev
2022-10-20Add Minifinder HDOPAnton Tananaev
2022-10-19Fix command queue issueAnton Tananaev
2022-10-18Add BCE test caseAnton Tananaev
2022-10-18Add BCE frame testsAnton Tananaev
2022-10-17Fix Suntech alert decodingAnton Tananaev
2022-10-16Improve Suntech supportAnton Tananaev
2022-10-15Fix MS SQL limit (fix #4958)Anton Tananaev
2022-10-14MiniFinder Rex bark alarmAnton Tananaev
2022-10-13Fix lint issuesAnton Tananaev
2022-10-13Refactor database code (fix #4961)Anton Tananaev
2022-10-13Support OBD6 status messageAnton Tananaev
2022-10-12Fix G1RUS decodingAnton Tananaev
2022-10-07Fix attributes test (fix #4956)Anton Tananaev